Skip to content

Splitting ottico passivo per ridundanza link#

ITNOG10 digest Program Core pick 20–21 April 2026

Mirko Mosca

  • Why: A physical-optics technique for link redundancy using passive splitters — cheap, unpowered redundancy directly in the PM's optics/cabling territory, and the kind of low-tech trick high-end roadmaps overlook.
  • What: Using passive optical splitting to provide link redundancy. (title only)
  • How: Presumably a splitter feeds two paths/receivers so a failure on one path does not drop the link; the design constraint to check is the splitter's insertion loss (roughly 3 dB per branch) eating into the loss budget.
  • Where applicable: Short-reach/DCI links and cost- or power-constrained sites; loss-budget math limits reach, so it does not scale to long spans without amplification.