Skip to content

Return loss problems associated with faster optical networks#

AusNOG 2026 digest Program Core pick 3–4 September 2026

Takaya Nakagawa - NTT Advanced Technology Corporation

Play the recording: Return loss problems associated with faster optical networks

  • Why: As links move from 10G to 100G/400G and beyond, reflections at connector points — not just insertion loss — become an error source. This is core physical-layer optics knowledge for anyone running DC or WAN fiber plants, and it comes with real experimental data rather than folklore.
  • What: A controlled demonstration that 100GBASE-LR4 links develop bit errors when total return loss degrades below the IEEE limit (21 dB) across multiple connection points. A single poor (<21 dB) connection point did not immediately produce errors, but three poor points did, via multiple reflections between connectors (eye closure, jitter, rising BER). BER worsens as received power drops, and the three transceivers tested showed materially different tolerance to poor return loss. The talk also catalogues causes: dust contamination takes a clean connector pair from 0.05 dB IL / 52.6 dB RL to 1.1 dB / 22.7 dB; hand oil to 44.2 dB RL; a partially seated connector hit 13.8 dB RL; legacy PC polishing only guarantees ~25 dB. Notably, poor reflection points spaced 20 km apart produced no errors — the reflected signal is attenuated over distance.
  • How: Testbed of a 100GBASE-LR4 link with variable optical attenuator and deliberately poor connectors, measuring eye diagrams and BER across three transceiver vendors; PAM4 (400G+) flagged as even more exposed since it is now mainstream.
  • Where applicable: Any single-mode plant with dense patching — meet-me rooms, DC cross-connects, ROADM/MUX shelves — especially at 100G+ and at low receive power. Broadly applicable physics, though NTT-AT sells connector cleaning/polishing products, so the "Clean Before Connect" conclusion aligns with their business.